| Water Still (Manasty Pattern) Wall hangingCI -160 |
| |
Electrically operated for getting pyrogen free distilled water automatically. This unit has seamless condenser with automatic ejection device which operates automatically when water vessel gets dried i.e. run with or without water automatically. |
| |
Model |
Output Capacity |
WSMP-01 |
2 ltrs per hour |
WSMP-02 |
3/4 ltrs per hour |
WSMP-03 |
5/6 ltrs per hour |
WSMP-04 |
8 ltrs per hour |
WSMP-05 |
10 ltrs per hour |
|
| |
| Water Still (Barnstead Pattern)CI -161 |
| |
Double wall stainless steel sheet filled with glass wool for heat insulation. Table model working on 220V AC single phase.
|
| |
Model |
Output Capacity |
WSBP-01 |
4/5 ltrs per hour |
WSBP-02 |
8/9 ltrs per hour |
WSBP-03 |
15/16 ltrs per hour |
WSBP-04 |
25/26 ltrs per hour |
|
| |
| Soxhlet Extraction UnitsCI -162 |
| |
Heavy & Thick duly powder coated CRC sheet finished and other parts duly chrome plated. Housing for surface temperature up to 300°C. Provided individual on-off switches & Pilot lamps. Work on 220V AC 50 Hz single phase.
|
| |
MANTEL TYPE / HEATER TYPE |
Model |
Capacity |
Ratings |
Without Glass Parts |
Glass Parts |
SEM-01 |
Unit of 3 Mantels |
600 Watts |
|
|
SEM-02 |
Unit of 6 Mantels |
1200 Watts |
|
|
|
| |
Hot plate type /BATH TYPE |
Model |
Capacity |
Heating Type |
Without Glass Parts |
Glass Parts |
SEH-01 |
Unit of 3 Heater |
Heater/Bath Type |
|
|
SEH-02 |
Unit of 6 Heater |
Heater/Bath Type |
|
|
|
| |
| Kjeldahl Digestion UnitCI -163 |
| |
The unit useful for estimation of Nitrogen contents in substances by digestion in 300 ml & 500 ml flasks provided (optional) with fume duct made of lead & pair of hangers. Individual on/off switches and one energy controller for all units is provided.
|
| |
Model |
Capacity |
Heating Type |
KDG-01 |
Unit of 3 test |
Mantel Type |
KDG-02 |
Unit of 6 test |
Mantel Type |
KDG-03 |
Unit of 3 test |
Heater Type |
KDG-04 |
Unit of 6 test |
Heater Type |
|
| |
| Kjeldahl Distillation UnitCI -164 |
| |
As above but Asbestos tops mounted on mild steel tubular stand. Provided with condenser clamps and water manifold.
|
| |
Model |
Capacity |
Heating Type |
KDS-01 |
Unit of 3 test |
Mantel Type |
KDS-02 |
Unit of 6 test |
Mantel Type |
KDS-03 |
Unit of 3 test |
Heater Type |
KDS-04 |
Unit of 6 test |
Heater Type |
|
| |
| Kjeldahl Distillation & Digestion Combine UnitCI -165 |
| |
One single & heavy M.S tubular stand is provided with two heating shelves, one above the other. A fume duct holder and a heating box are supplied for digestion unit and this heating unit have individual on - off switches in the upper portion another heating unit with a condenser rack is provided. |
| |
Model |
Capacity |
Heating Type |
KDDC-01 |
Unit of 3 test |
Mantel Type |
KDDC-02 |
Unit of 6 test |
Mantel Type |
KDDC-03 |
Unit of 3 test |
Heater Type |
KDDC-04 |
Unit of 6 test |
Heater Type |
|
| |
Optional : For CI – 162/163/164/165
1. Energy regulator |
| |
| Micro Kjeldahl Digestion UnitCI -166 |
| |
Useful for estimation of Nitrogen content in the substance by digestion in micro flasks of capacity 30, 50 & 100 ml. Made of thick duly powder coated CRC sheet finished with PVC fume duct & pairs of hangers etc. Work on 220/230V AC.
|
| |
Model |
Capacity |
E.R. |
MKD-01 |
3 Test (Mantle type) |
0.3 Nos. |
MKD-02 |
6 Test (Mantle type) |
0.6 Nos. |
|
| |
| Glass Distillation UnitCI -167 |
| |
With Automatic electrically heated all glass. Complete with stand, Clamp, Switch, Boards heater embedded in spring glass coil, double walled condenser.
|
| |
Model |
Capacity |
Single stage |
Double stage |
Triple stage |
Spare Flask with Heater |
Spare Condenser |
AGD-01 |
3 ltrs. |
|
|
|
|
|
AGD-02 |
5 ltrs. |
|
|
|
|
|
AGD-03 |
10 ltrs. |
|
|
|
|
|
Automatic cut off device with electrodes |
|
|
|
|
|
|
| |
| Water Deionizer (Double Bed) With Digital Conductivity MeterCI -168 |
| |
Deionization of water is the removal of cation and anions of the substances dissolved in it. Inbuilt pre filter, cation & anion resin columns, AC and DC of 9V small battery with one PVC chemical proof regeneration tank. A set of Flexible polythene tube connection. Deionized water will have the conductivity of less than 10 micro siemens / cm. & pH of 7.5 to 9.
|
| |
Model |
DWD-01 |
DWD-02 |
DWD-03 |
DWD-04 |
DWD-05 |
DWD-06 |
DWD-07 |
Capacity/hr. |
50 ltrs. |
70 ltrs. |
100 ltrs. |
200 ltrs. |
300 ltrs. |
500 ltrs. |
750 ltrs. |
|
| |
| Deionizer Four Bed (Fb) With Digital Conductivity MeterCI -169 |
| |
 |
Model |
FBD-01 |
FBD-02 |
FBD-03 |
FBD-04 |
FBD-05 |
Capacity/hr. |
70 ltrs. |
100 ltrs. |
200 ltrs. |
300 ltrs. |
500 ltrs. |
|
|
| |
| Double Stage With Double Bed With Digital Conductivity MeterCI -170 |
| |
 |
Model |
DDB-01 |
DDB-02 |
DDB-03 |
DDB-04 |
DDB-05 |
DDB-06 |
Capacity/hr. |
70 ltrs. |
100 ltrs. |
200 ltrs. |
300 ltrs. |
500 ltrs. |
750 ltrs. |
|
|
| |
| Mixed Bed Deionizer With Digital Conductivity MeterCI -171 |
 |
Model |
MBD-01 |
MBD-02 |
MBD-03 |
MBD-04 |
MBD-05 |
Capacity/hr. |
70 ltrs. |
100 ltrs. |
200 ltrs. |
300 ltrs. |
500 ltrs. |
|
|
| |
| Double Bed With Mix Bed With Digital Conductivity MeterCI -172 |
| |
 |
Model |
DBMB-01 |
DBMB-02 |
DBMB-03 |
DBMB-04 |
DBMB-05 |
DBMB-06 |
Capacity/hr. |
70 ltrs. |
100 ltrs. |
200 ltrs. |
300 ltrs. |
500 ltrs. |
750 ltrs. |
|
|
| |
| Quartz Distillation Quartz Boiler & Borosilicate Condensor with Automatic Cut-OffCI -173 |
| |
 |
Model |
UQBC-01 |
UQBC-02 |
UQBC-03 |
UQBC-04 |
UQBC-05 |
Capacity/hr. |
1.0 ltrs/hr. |
2.0 ltrs/hr. |
3.0 ltrs/hr. |
4.0 ltrs/hr. |
5.0 ltrs/hr. |
SINGLE STAGE |
|
|
|
|
|
DOUBLE STAGE |
|
|
|
|
|
|
|
| |
| Quartz Boiler & Quartz Condensor with Automatic Cut-Off |
| |
Model |
UQQC-01 |
UQQC-02 |
UQQC-03 |
UQQC-04 |
UQQC-05 |
UQQC-06 |
UQQC-07 |
Capacity/hr. |
1.0 ltrs/hr. |
1.5 ltrs/hr. |
2.0 ltrs/hr. |
2.5 ltrs/hr. |
3.0 ltrs/hr. |
4.0 ltrs/hr. |
5.0 ltrs/hr. |
SINGLE STAGE |
|
|
|
|
|
|
|